C:\Documents and Settings\Administrator\Desktop\tw_cli-windows-x86-9.4.1.3>tw_cli.exe
//EDGWIN> info c0
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
------------------------------------------------------------------------------
u0 RAID-5 OK - - 64K 1629.74 ON OFF
Port Status Unit Size Blocks Serial
---------------------------------------------------------------
p0 OK u0 233.76 GB 490234752 WD-WCANY2312070
p1 OK u0 233.76 GB 490234752 WD-WCANY2311250
p2 DEVICE-ERROR u0 233.76 GB 490234752 WD-WCANY1796905
p3 OK u0 233.76 GB 490234752 WD-WCANY2265331
p4 OK u0 233.81 GB 490350672 WD-WCAT1A636279
p5 OK u0 233.81 GB 490350672 WD-WMAYP3458409
p6 OK u0 233.76 GB 490234752 WD-WCANY2312032
p7 OK u0 233.81 GB 490350672 WD-WCAT1H074670
//EDGWIN> maint remove c0 p2
Removing port /c0/p2 ... Done.
//EDGWIN> info c0
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
------------------------------------------------------------------------------
u0 RAID-5 DEGRADED - - 64K 1629.74 OFF OFF
Port Status Unit Size Blocks Serial
---------------------------------------------------------------
p0 OK u0 233.76 GB 490234752 WD-WCANY2312070
p1 OK u0 233.76 GB 490234752 WD-WCANY2311250
p2 NOT-PRESENT - - - -
p3 OK u0 233.76 GB 490234752 WD-WCANY2265331
p4 OK u0 233.81 GB 490350672 WD-WCAT1A636279
p5 OK u0 233.81 GB 490350672 WD-WMAYP3458409
p6 OK u0 233.76 GB 490234752 WD-WCANY2312032
p7 OK u0 233.81 GB 490350672 WD-WCAT1H074670
//EDGWIN> info c0
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
------------------------------------------------------------------------------
u0 RAID-5 DEGRADED - - 64K 1629.74 OFF OFF
Port Status Unit Size Blocks Serial
---------------------------------------------------------------
p0 OK u0 233.76 GB 490234752 WD-WCANY2312070
p1 OK u0 233.76 GB 490234752 WD-WCANY2311250
p2 NOT-PRESENT - - - -
p3 OK u0 233.76 GB 490234752 WD-WCANY2265331
p4 OK u0 233.81 GB 490350672 WD-WCAT1A636279
p5 OK u0 233.81 GB 490350672 WD-WMAYP3458409
p6 OK u0 233.76 GB 490234752 WD-WCANY2312032
p7 OK u0 233.81 GB 490350672 WD-WCAT1H074670
//EDGWIN> info c0
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
------------------------------------------------------------------------------
u0 RAID-5 DEGRADED - - 64K 1629.74 OFF OFF
Port Status Unit Size Blocks Serial
---------------------------------------------------------------
p0 OK u0 233.76 GB 490234752 WD-WCANY2312070
p1 OK u0 233.76 GB 490234752 WD-WCANY2311250
p2 NOT-PRESENT - - - -
p3 OK u0 233.76 GB 490234752 WD-WCANY2265331
p4 OK u0 233.81 GB 490350672 WD-WCAT1A636279
p5 OK u0 233.81 GB 490350672 WD-WMAYP3458409
p6 OK u0 233.76 GB 490234752 WD-WCANY2312032
p7 OK u0 233.81 GB 490350672 WD-WCAT1H074670
//EDGWIN> rescan
Rescanning controller /c0 for units and drives ...Done.
Found the following unit(s): [none].
Found the following drive(s): [none].
//EDGWIN> info c0
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
------------------------------------------------------------------------------
u0 RAID-5 DEGRADED - - 64K 1629.74 OFF OFF
Port Status Unit Size Blocks Serial
---------------------------------------------------------------
p0 OK u0 233.76 GB 490234752 WD-WCANY2312070
p1 OK u0 233.76 GB 490234752 WD-WCANY2311250
p2 OK - 233.81 GB 490350672 WD-WMAYP3479443
p3 OK u0 233.76 GB 490234752 WD-WCANY2265331
p4 OK u0 233.81 GB 490350672 WD-WCAT1A636279
p5 OK u0 233.81 GB 490350672 WD-WMAYP3458409
p6 OK u0 233.76 GB 490234752 WD-WCANY2312032
p7 OK u0 233.81 GB 490350672 WD-WCAT1H074670
//EDGWIN> info c0
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
------------------------------------------------------------------------------
u0 RAID-5 DEGRADED - - 64K 1629.74 OFF OFF
Port Status Unit Size Blocks Serial
---------------------------------------------------------------
p0 OK u0 233.76 GB 490234752 WD-WCANY2312070
p1 OK u0 233.76 GB 490234752 WD-WCANY2311250
p2 OK - 233.81 GB 490350672 WD-WMAYP3479443
p3 DEVICE-ERROR u0 233.76 GB 490234752 WD-WCANY2265331
p4 OK u0 233.81 GB 490350672 WD-WCAT1A636279
p5 OK u0 233.81 GB 490350672 WD-WMAYP3458409
p6 OK u0 233.76 GB 490234752 WD-WCANY2312032
p7 OK u0 233.81 GB 490350672 WD-WCAT1H074670
//EDGWIN> /c0/u0 start rebuild disk=2
Sending rebuild start request to /c0/u0 on 1 disk(s) [2] ... Done.
//EDGWIN> info c0
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
------------------------------------------------------------------------------
u0 RAID-5 REBUILDING 0 - 64K 1629.74 OFF OFF
Port Status Unit Size Blocks Serial
---------------------------------------------------------------
p0 OK u0 233.76 GB 490234752 WD-WCANY2312070
p1 OK u0 233.76 GB 490234752 WD-WCANY2311250
p2 DEGRADED u0 233.81 GB 490350672 WD-WMAYP3479443
p3 OK u0 233.76 GB 490234752 WD-WCANY2265331
p4 OK u0 233.81 GB 490350672 WD-WCAT1A636279
p5 OK u0 233.81 GB 490350672 WD-WMAYP3458409
p6 OK u0 233.76 GB 490234752 WD-WCANY2312032
p7 OK u0 233.81 GB 490350672 WD-WCAT1H074670
This entry was posted by Mary Heintz on June 8, 2012 at 6:32 pm under Raid.
Both comments and pings are currently closed.